Instrumentation Cable, 1 Pair 1.5mm² Bare Copper, XLPE Insulation, LSZH Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 1 Pair 1.5mm² Bare Copper, XLP Insulation, Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 2 Pairs 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 4 Pairs 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 8 Pairs 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 12 Pairs 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 16 Pairs 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 24 Pairs 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 1 Pair 2.5mm² Bare Copper, XLP Insulation, Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 4 Pairs 2.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 8 Pairs 2.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 12 Pairs 2.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 4 Triads 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 8 Triads 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 12 Triads 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 16 Triads 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 24 Triads 1.5mm² Bare Copper, XLP Insulation, Individual & Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Instrumentation Cable, 1 Triad 1.5mm² Bare Copper, XLP Insulation, Overall foil shield with drain wire, PVC Inner Jacket, Galvanized Steel Wire Armor, FRPVC Outer Jacket, BS EN 50288-7.

Fire Resistant Instrumentation Cable, 1 Pair 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 2 Pairs 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 4 Pairs 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 8 Pairs 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 12 Pairs 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 24 Pairs 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 1 Pair 2.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 4 Pairs 2.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 8 Pairs 2.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 16 Pairs 2.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Individual & Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Fire Resistant Instrumentation Cable, 1 Triad 1.5mm² Bare Copper, Mica Glass Tape (MGT), XLP Insulation, Overall foil shield with drain wire, LSZH Inner Jacket, Galvanized Steel Wire Armor, LSZH Outer Jacket, BS EN 50288-7, BS 6387 CWZ.

Designed for applications which are used for RS 232/422/485, CANBUS, MODBUS communication protocols. Cable applications include motion oriented machine, machine control networks, temperature controllers, control panels, machine cutting tools, auxiliary equipment, SCADA communications, etc. These cables are used in emergency evacuation / shutdown systems in building automation, offshore, oil & gas and railway applications and are flame retardant according to IEC 60332-3-22 Category A.